Incinerator

Product Description

Technology Respond(FAQ) 

Q: What is kind of waste may use within this gear?  A: This gear for medical waste, pet animal, Municipal waste, live squander. Prohibit any volatile and radiation substance, liquid waste and gas waste. 

Q: Incinerator Smoke Standard  A: China Government Standard: No. GB18484-2001.  The animal/pet combustion speed around 2/3 of ordinary capacity. 

Clover incinerator use time per day up to 24 hours. Between each feed/combustion time, there are approximately 0.5-1 hours heating time incinerator furnace manufacturer, incinerator hospital cost, incinerator in hospital, incinerator manufacturer in shanghai, incinerator producers in usa, and time for feeding squander. Actual combustion time per day is around 16 hours. The lifetime of incinerator involving 5-10 year based on use. 

Generally, we proposition little laboratory, little clinic use capacity under 20 kgs per hour. When incinerator use in hospital, then please calculate the waste output around 2kgs per people per day. If there are 200 sickbed at the hospital, that’s imply you need one incinerator capacity around 400kgs per day, switch to capacity per hour is approximately 30-40 kgs per hour. According the operation time per day, waste material, budget, growth, etc, you may use capacity from 30-50 kgs each hour incinerator.  *The best way to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. 

Q: Meeting and Testing  A: We supply all files and incinerators simple to setup and functionality. Client can send people come to our factory to learn operation and installation. Generally, We do not send engineer to local site or even request. The shipment price is additional based on order. 

Q: Combustion Temperature  A: The first combustion chamber: 800-1000 centi degree.  The next combustion chamber: 1000-1200 centi degree. 

Q: Incinerator Control Mode  A: Default Control manner is common control case. PLC mode based on model and order. 

Q: Operation and maintenance costs  A: Operation price based on fuel consumption rate and power/staff, etc. 

Annual approximately $500-$1000USD annually maintenance according version, use situation. 

One person can service 02 unit incinerators. The team should have fundamental electrician knowledge to operate/inspect/maintaince incinerator/burner/blower based on operation user guider, and know risk of medical waste to protect worker self with essential protection element. 

Q: The Residency time in secondary combustion chamber  A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: sales@hiclover.com Email: hicloversales@gmail.com