Blog
animal waste incinerator manufacturer

Technical specification for burning machine,animal waste incinerator manufacturer
1.Two systems are required to be installed in the south of the Kingdom of Saudi Arabia. The two systems will be used by custom authority to burn different kinds of drugs. All need equipment must be provided.
2.Warrantee:  booth systems must be provided with 3 years warrantee from the date of acceptance. All needed spare parts, preventative maintenance repair and corrective maintenance must be included in the cost and provided to the customer.
3.All needed electric and water connections must be provided.
4.Both systems must be of high quality and must be environmental friendly.
5.The capacity of each system should be up to 100 kg/hr.
6.The system must have automatic feeding.
7.Each system must consists of two burning  rooms, one primary room for burning the drug and another room for burning the gases  that emit as a result of primary burning.
8.The oven must be made of steel that is rust resistance and with thickness not less than 6 mm.
9.Each system must be of high efficient in burning different kinds of drugs, and should have 99.9% efficiency for burning organic materials.
10.Waste products should not exceed 5%.
11.System must have automatic ignition system.
12.System should use diesel (HSD) as fuel and should not consume more than  8 to 10 lt/hr .
13.Each system should be provided with fuel tank  of size adequate to operate the system for one full day.
14.The temperature in the primary room should be 850 C ± 50 C. the system should also be capable to operate up to 1050 C ± 50 C. the system should be capable of continues operation and should be provided with cement layer insulator with adequate thickness.
15.Oven should be provided with heat insulator to allow easy operation.
16.Gas should remain in the secondary room for not more than 1.5 second.
17.The primary burning room  should have at least 2 burners.
18.The secondary burning room should have one burner.
19.  Each system should have doors for ash, exit for air to the chimney and windows to allow looking inside and for maintenance.
20.Each system should have filtering system for gas processing with 2 tanks using ordinary water. Each water tank should have capacity of 1000 lt and should be fixed to the system and provided with water level indicator.
21.Each system should have special technology for separating waist products and humidity after gas processing.
22.Each system should have cooling capability after operation.
23.Each system m should be provided with exhaust pipe with 250 mm diameter and 10 m high. The base of the exhaust system should be 1000 mm. The exhaust pipe should be 6 mm and should be provide with heat insulator.  The exhaust system should be provided with pressure indicator. It should also provide with ladder and Lightning Arrestor.
24.Electric power: should be 220 volt, 3 phase, 60 Hz, and the motor should not be less than 15 HP.
25.Each system should be provided with control panel and indicators and needed safety equipment and alarm systems. The control panel should show at least temperature in both the primary and secondary rooms and injectors of the filters and load.
26.Each system should be provided with alarm system for any breakdown or defect of any component of the system.
27.The following personal protective tools must be provide:
a.Heat resistant garments for 20 persons.
b.Heat resistant goggles for 20 persons.
28.All components of each system should be painted with silver color that is heat resistant.

Blog
Waste Incineration HICLOVER Model TS75
Waste Incineration HICLOVER Model TS75 

Items/Model

TS75(PLC)

Picture

Principle

Waste Incineration

Burn Rate

Average 75 kg/hour

Feed Capacity

Average 150kg

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

770L

Internal Dimensions

100x81x95cm

Secondary Chamber

385L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

0.7Kw

Oil Consumption (kg/hour)

Average 16.9

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

100L

Feed Door

99x91cm

Chimney

3Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

4500kg

External Dimensions

2.30mx1.30mx2.55m

15kg-20kg LPG driven Clinical waste incinerator to burn highly infectious materials
100kg per hour *medical incinerator* is needed in the size of a *20ft container.* 
100Kg/Hour Burning rate with
       with Secondary burning Capacity
Je suis intéressé par votre produit Longue durée de vie Pet Crematory (YD-15), je veux savoir plus de détails sur:
Veuillez me proposer une liste de prix précis.
Ce serait formidable si vous pouvez me faire parvenir plus de détails sur ce produit.
Human Cremator For Crematorium Cremation Machine 
Automatic Medical Waste Incinerator with Auto Loading Systems.
The working capacity 150 KGs EACH BATCH
incinerator to be used for medical/clinical wastes incineration 
Blog
medical waste incinerator china

medical waste incinerator china, Design, supply and manufacture ex works of one Surefire Manual Load TS50/1 Medical/General waste incinerator as detailed below: –

·         Waste type: Mixed type o,1,2,3,&4 hospital/clinical bio hazard waste

·         Waste density: 125 to 350Kg/M3

·         Waste CV: 4000 KCAL/kg

·         Moisture content: 10-25%

·         Estimated ash residue: 5-10%

·         Nominal capacity: 30Kg/hour batch load

·         Secondary chamber: 0.5 second @ 850oC
·         Compact laboratory style

·         Two combustion chambers

·         Ecologically friendly

·         Up to 50kg of waste / hour

·         To be used for animals

Blog
Medical Waste Incinerator HICLOVER TS10 PLC 10kgs per hour
medical waste incinerator iraq price HICLOVER TS10 PLC 10kgs per hour

Items/Model

TS10(PLC)

Picture

 

Burn Rate

Average 10 kg/hour

Feed Capacity

Average 20kg/feeding

Control Mode

Programmable Logic Controller(PLC) Panel

Combustion Chamber

100L

Internal Dimensions

50x50x40cm

Secondary Chamber

50L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

0.5Kw

Oil Consumption (kg/hour)

average 8.4kg/hour

Gas Consumption (m3/hour)

average 10.1m3/hour

Temperature Monitor

Yes

Temperature Protection

Yes

Oil Tank

100L

Feed Door

30x30cm

Chimney

5 Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

1500kg

External Dimensions

140x90x120cm


























hazardous waste disposal companies
HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-30

Blog
Automatic PLC controller incinerator plant with Dual heat burners and dual chamber HICLOVER YD-30C with Wet Scrubber

Item

Specification

Model

YD-30C

Main Product List

Primary Combustion Chamber(Main body stainless steel)

Secondary Combustion Chamber(Main body stainless steel)

Mix-Combustion Chamber

Wet Scrubber( Washing Tower)(Main body stainless steel)

Incinerator Control Case

Chimney:5.0Meters

*(upgrade to Stainless Steel, free cost)

Italy gas burner: 02 sets

Oil Tank (if oil fuel): 100Liters

Automatic PLC controller incinerator plant with Dual heat burners and dual chamber.
Burning capacity up to 30 Kg per hour.
Water showering cyclone air cleaner
Stain less steel 304 grade sheet for water scrub chamber
Time up to 250 mints.
Fully automatic electric control circuit with timers
Primary temperature 800-1000 deg C
Secondary temperature1000-1200 deg C
Manual loading /unloading
Automatic start at power fail during process
Fast temperature rise control automatic detects fast burning materials and save burner fuel consumption by turn off /on burner automatically. Suitable for waste of hospitals
Number of burner   2 Nos
Voltage  380V 50Hz
Operational enjoinment          5 C 60 C Humidity 10 C 90%

Fuel type               Natural gas Number of chamber      02 Nos

 


HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-28

Blog
chinese incinerator manufacturers

In a simple design with a metal steel drum electric. including:
A cage for receipt of biomedical waste;
A combustion chamber with fireplace with a filter to retain ashes;
A cover;
An air supply;
A turbine  allowing the supply of the air.
Combustion temperature: 1800 ° C. Compliance with European standards.
Comes with all necessary accessories
Supply of incinerator model PDR-18 with:

·        Capacity 100 kg/hr of waste containing up to 85% moisture

?      Two combustion chambers

·        Two fully automatic, oil fired, pressure jet burners

·        Panel board

·         Diesel tank of capacity 250 It. with 2 diesel pipelines, filter and valve.
Type: for animals waste
Capacity: 30 kg per hours for a maximum load of 120 kg.
GLP Gas
Voltage: 110V-120V
Semiautomatic control board
Stainless steel chimney, 3.5 meters above the incinerator.
High temperature painting for all the incinerator.
Front door for loading and unloading.
Fuel    Diesel Oil 8/ kerosene
Capacity (m3)    0.57
Ave Capacity    50 kg per hour
Ave time for Burnout     5 hrs
External Dimensions
Length    2000mm
Width    1100mm
Height including flue    3500mm
Door opening
Internal Dimensions
(primary chamber)
Length    1200mm
Width    620mm
Height     660mm
Operation
Min. operating temperature    9500C
Max. operating temperature    13200C
Residency time in second chamber    2.0 seconds
Weight    1850kgs
Ancillaries
Operating and maintenance manuals
Recommended Spare list
300 liter fuel tank
Plant burning rate – 100kg/hr

Fuel – Diesel oil   – 35 sec Redwood

Overall dimensions are as follows:

Width    2261mm

Length  3264mm

Chimney Diameter  –  390mm

Chimney Height      –  8000mm
chinese incinerator manufacturers, We process 8-10 ton waste of sheep carcass and its byproduct per day. We are looking for the equipment: combustion burners(combined fuel supply:natural gas and diesel),control panel and filter system. The diameter of the incinerator is 20 cm. Lower calorific power of the waste is 4KW/KG. Heating power 4000KW

Blog
Large Capacity Animal Pet Cremation HICLOVER Model A1500 with E-Power Auto. Door
Large Capacity Animal Pet Cremation HICLOVER Model A1500 with E-Power Auto. Door

Model

A1500

Internal Dimensions

150 x 100 x 96cm

Suit for Animal

Cat – yes

Dog – yes

Pig – small

Cow – small

Main Product List

Primary Combustion Chamber

Secondary Combustion Chamber

Mix-Combustion Chamber

Smoke Filter Chamber

Incinerator Control Case

Chimney:10.0Meters

*(upgrade to Stainless Steel, free cost)

Italy oil/gas burner: 03 sets

Oil Tank (if oil fuel): 500Liters

Design for Pets Cremation Business

Movable platform & Auto. Door & Fire/Flame Checking Hole

Independent Position for Small Pet





















HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-28

Blog
hospital incinerator manufacturers

The Incinerator Plant is output wastes incineration from Different petrochemical units. In this project we want to incinerate all output wastes from petrochemical units and also produced high pressure steam from incinerator plant heat generated.
At first output waste from petrochemical collects and transfers to transit and sorting center in various forms. Input feeds of incinerator plant are shown in below table:

hospital incinerator manufacturers, Waste streams of petrochemical unit collect and store in Transit and Sorting Center.
In Transit and Sorting Center one laboratory must be considered.
In this center, waste will be classified in two groups:
–    Unsuitable for burning
–    Suitable for burning
Unsuitable waste for burning can be divided into the 4 categories:
–    Buried materials
–    Materials (wastes) that need to be stabilized before buried
–    Materials (wastes) that can be sold.
–    Wastes that can be returned to petrochemical.
Suitable wastes are classified into the two categories:
–    Input wastes to rotary kiln, consist of solids and waste fluids.
–    Input wastes to static kiln, consist of clean fluids and gasses.
All solid wastes must be transferred to storage pit from Transit and Sorting Center. Solid wastes storage pit is input of rotary kiln.
All fluid wastes must be stored and stabilized in Transit and Sorting Center. All storage and stabilization devices or facility must be considered. Storage and stabilization devices (facility) consist of:
Tanks, Pumps (Transfer, Loading & Unloading), Agitator (Mixer), Blanketing System, Flare system, Instrumentation and Control Systems, etc
Storage and stabilization capacity must be considered based on worst case (shut down).
Generally incinerator plant consists of two similar trains (capacity of each train is 100%). Each train consists of a rotary kiln and a static kiln.

Blog
HICLOVER Incinerator mobile small With Wheel and Brake

Model

YD-30 Mobile Type

Picture

 

Burning Rate

Average 30 kgs/hour

Feed Capacity

Average 60 kgs/feeding

Chamber Main Body

Stainless Steel

Mobile Function

With Wheel and Brake

Primary Combustion Chamber

280 Liters

Secondary Combustion Chamber

150 Liters

Mix Combustion Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

1.5 Kw

Fuel Type

Diesel Oil

Burner

Italy Original

Oil Consumption (Diesel Oil)

Average 13.3 kg/hour

Internal Dimensions

80 x 60 x 60cm (primary chamber)

External Dimensions

125 x 90 x 260cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

100 Liters

Door Opening

50 x 50cm

Chimney Length

2.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

1600 kgs

Operation Technical Specifications

Primary Chamber Temperature

800-1000

Secondary Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Burning Efficiency

98%

Waste Lower Calorific Power

3000Kcal


HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-28

Blog
medical waste incinerators manufacturers

chemical agents to be utilized:
10% heptyl (unsymmetrical dimethylhydrazine) water solution,
heptyl (unsymmetrical dimethylhydrazine) vapour with 0.8 to 1.0 kg/m3 concentration,
10% azotic (nitric) acid water solution,
azotic (nitric) acid vapour with concentration up to 1.1 kg/m3;
2.    neutralization method: thermal decomposition;
3.    neutralization temperature: +800?C to +1200?C;
4.    performance:
?    vapour capacity: 70 to 200 m3/h,
?    water solution capacity: 50 to 500 l/h;
5.    inlet pressure: up to 2 bars;
6.    automatic control system;
7.    overall dimensions shall allow for mounting the unit on a vehicle chassis.
medical waste incinerators manufacturers General Specifications
6mm plate steel sheel construction
11cm 1400 o C Refractory L iner
Temperature controlled Burners
Secondary combustion Burners
Interlock Switch on Load Doors
Separate Ash Door
One Second secondary Residence @ 1000 o C
400 ° C Silicone Based Paint Finish.
Alloy Temperature Sensor
Factory wired and tested
Capacity-20 kg / hr
Primary Chamber-1607 L
Hearth Area-1:36 sq. m
Secondary Chamber-694 L
Primary Burner (oil)-420,000 btu
Secondary Burner (oil)-900,000 btu
secondary Combustion-1/6 hp
Exhaust Stack-46cm x 6m
Electrical Service-220/50
Weight System-5.700 kg
Dimension “D”-152cm
Load Port Height- 60x 60 cm
Ash Port Height -36 x 36 cm