waste incinerator means incineration the waste by incineration. we supply waste incinerator for medical hospital waste, pet cremation and animal incineration and other solid waste treatment. the waste incinerators have 2 combustion chamber, the first burner burn the waste in the primary combustion chamber and the other burner burn the smoke from primary combustion chamber. the smoke will be filtered by smoke filter chamber and then out. the waste incinerator use stainless steel chimney which is long life time and all the burner made in italy.
incinerator 500kg per hour, which model is YD500. the fuel type is diesel oil or natual gas or LPG. this model incinerator burning rate is 500kgs per hour and the feeding capacity is average 800kgs per time, accordingly to detail waste material. YD500 is also suit for big animal cremation and we supply custom made incinerator accordingly to different use. incinerator 500kg per hour is average capacity for medical waste and this is also suit for hospital waste, animal cremator and other solid waste management.
portable incinerator means a small incinerator so end user can move it to other place. we made portable incinerator and the weight under 2000 kgs, the burning rate from 5kgs per hour to 20kgs per hour. all designed with three combustion chamber and two oil or gas burner. this kind of portable incinerator is cheap cost for small waste out put.
small scale incinerator means small burning rate (capacity), average from 5kgs per hour to 20 kgs per hour. this kind of incinerator mainly for small hospital clinic or laboratory, etc. but all of them design with double combustion chamber to best waste treatment. some place or department, small scale incinerator is necessary for goverment rule request and the end user need a simple cheap equipment, you can contact with to design with more cheaper cost but simple for you.
Application Scope: 1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 3. Community & Sea Port & Station: Municipal Solid Waste, etc. 4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation
Company License No.,: 320105000138343 Taxation Certificate No.: 320105571573734 Export Business Certificate No.: 3201571573734
Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, what is a biological incinerator for pets, what is double chamber incierator, what is the average cost for a medical incinerator, what is the cost of a pet cremation incinerator, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world.
Key Features: * All models with Dual combustion chamber. * Stainless Steel chimney/stack, long lifetime. *according to order * High temperature, long lifetime of incinerator. * Free or minimum installation on site. * High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. * PLC Control Plane. *according to order * New Design for pet animal cremation business. * One year warranty on incinerator and parts in stock. Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we supply different series for local customer requirements and united states animal incinerators for sale, us crematorium manufacturer, usa medical waste incinerator, use natural gas incinerator, used batch load animal incinerators for sale by owner, design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world.
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project.
We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction with medical disposable, biological waste, medical plastic waste, hazardous waste, red bag waste, needle disposal, gauze and bandages, sealed sharp containers, pathological waste, trace-chemotherapeutic wastes, etc.
Our range of incinerators cater for small to large scale animal cremation related businesses, such as poultry farms, cattle farms, sheep farms, pig farms, stables, kennels, testing laboratory, catteries, pet crematoriums.
The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber again to make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection.
System solutions for medical waste environmental, including waste incineration, smoke emission treatment, high-temperature sterilization, ultraviolet sterilization lamp, waste shredder, needle destroyer, medical waste package, sharp containers, etc.
The pet cremation equipment humanized design with movable platform, small space covers for modern pet cremation business owner all over the world.
The containerized mobile incinerator mounted in ISO container before leave factory, pre-installation, no incineration house build construction, movable by truck and ultraviolet lamp sterilization inside.
HICLOVERis growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan.
We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products and friendly service.
— Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator.
— Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators.
— System solutions for medical waste environmental.
— High burn rate, from 5kgs to 1000kgs per hour.
— New Design for pet animal cremation business.
— HICLOVER, trusted partner with years of experience.
the animal crematory equipment function like other incinerators, but there are also some difference, some key point is door opening(we can feed the pet), oil or gas operation cost, moveable feeding door, smoke enviromental friendly, if we can collect ash, easy to use it, good service from pet incinerator manufacturer,etc.
1. For clinic,lab, small hospital with low waste output capacity, no condition with other medical waste treatment(Underdeveloped country or area, or emergency situations ).
2. Doctor, nurse treat the syringes, needle, infusion set immediately after use, plug to play, no dispersion risk.
3. melting the syringes needle with 1250Celsius high temperature to metal slag, sterilization immediately. Destroy syringes, infusion set, can not use again.
Medical Needle Incinerator: Melt the needle waste, cut off syring tube with needle, cut off the infusion tube.
The plant must have four distinct sections that demonstrate three principles of turbulence, residence time and temperature retention. The regulated sections may include but not limited to:
Overall plant layout
Feed chamber/charging
Primary combustion chamber
Particulate scrubbers
Acid gas
The stack/chimney.
Minimum capacity of primary chamber = 10cubic meters
Burn rate (rate of waste incineration) = 10 kg per hour
Should have a full width counterbalance loading door allowing easy access to the main chamber for loading and removing ash.
The INCINERATOR should be NEMA approved in accordance with Environmental management and coordination (Waste management) Regulations of 2006.
Scope Of Work
The work specified in the contract will include.
Supply, install and commission an incinerator as provided in the technical specifications
Provision for adherence to OSHA and other statutory requirement relating to Health and Safety of workers during execution of the works covered in this
Assessment and preparation and construction of a standard incinerator shed with one waste storage room ( see the design )
Provision of operation and maintenance manuals and drawings complete with maintenance schedule and
To enable the Employer undertake conclusive evaluation of the tender, tenderers are requested to submit with their offers the detailed specifications, drawings and catalogues with Commissioning and maintenance instructions for the Incinerator they intend to Supply, install and commission.
Tenderers who fail to comply with this requirement fully shall have their tender rejected.
TECHICAL SPECIFICATIONS OF THE INCINERATOR
3.1 Feeding and Charging
Controlled hygienic mechanical feeding that does not negatively influence the air temperature in the primary and secondary chambers of the incinerator shall be used.
Primary Combustion
This chamber should be equipped with burners that use low sulphur
The chamber should ensure a minimum exit temperature of 850 degrees
This unit should operate at over 1100 deg C to ensure complete
This chamber should be equipped with burners that use low sulphur
Heavy-duty steel casing
High quality refractory lining and insulation
Large full size top load door and liquid retention
1 x oil fired ignition burners operated on/off
Secondary Combustion Chamber (After burner)
Heavy-duty steel casing
High quality refractory lining and insulation
1 x oil burner
Should be fitted with burners that use low sulphur
Ensure secondary air supply is controlled.
Ensure residence time is not less than two seconds.
Ensure that the gas temperature as measured against the inside wall in the secondary chamber and not in the flame zone is not less than 1100 degrees
Ensure the emitted oxygen content of the emitted gases is not less than 11%
Ensure both primary and secondary combustion temperatures are maintained until all waste is completely
Particulate Removers
A mechanical particulate collector must be incorporated after secondary combustion chamber for removal of particulate pollutants entrained in the flue gas stream. The particulate collectors may include any of the following or a combination thereof:
Cyclone separator
Electrostatic precipitators
Fabric filters
Chimney/Stack
The chimney should have a minimum height of 10 meters above ground level and clear the highest point of the building by not less than 3 meters for all The topography and height of adjacent buildings within 50 meters radius should be taken into account.
The chimney should be visible to the operator from the feeding
The minimum exit velocity should be 10 meters per second and at least twice the surrounding wind speed (Efflux velocity = wind speed x 2) whichever is higher to ensure no down washing of exiting
The point for measurement of emissions shall be
Instrumentation
Instrument for determining the inside wall temperature and not burner flame temperature must be provided for both primary and secondary
An audible and visible alarm must be installed to warn the operator when the secondary chamber temperature drops to below the required
A carbon monoxide and oxygen meter/recorder should be
A smoke density meter/recorder should be
A solid particulate meter/recorder should be
Any other instrument that may be considered
Location / Siting of the Incinerator
a) The incinerator must be sited in accordance with the relevant local municipal authority planning regulations and the topography of the site must be compatible with premises in the
Emission Limits
Combustion efficiency (C.E) shall be at least00% where C.E = %Carbon dioxide x 100 / [% Carbon dioxide + carbon monoxide]
The temperature of the primary chamber shall be 800 +/- 50 degrees centigrade
The secondary chamber gas residence time shall be at least 1 second at 1050 +/- 50 degrees centigrade with 3% oxygen in the stack
Opacity of the smoke must not exceed 20% viewed from 50 metres with naked
All the emission to the air other than steam or water vapour must be odourless and free of mist, fume and
A 99.99% destruction and removal efficiency (DRE) for each principal organic hazardous constituent (POHC) in the waste feed where DRE [ ( Win – Wout) /Win ] x
100 where Win = mass feed rate of the POHC in the waste stream fed to incinerator and Wout = mass emission rate of POHC in the stack prior to the release to the atmosphere.
The average dioxin and furan concentration in the emission should not exceed 80mg/m3 total dioxins and furans if measured for a period of 6 to 16
Ease of Use
Auto
No pilots to
Automatic control and temperature monitoring
Built-in skid facilitates placement
Fuel Efficiency
Rapid incineration means low fuel
Up to 20kgs per hour (dependant on application).
Thick refractory lining rated to 1400 deg C in main chamber retains heat, increasing
Quality Built to Last
Heat resistant 3mm
Stainless steel
Key Features
Low running and maintenance costs
Fully Automatic and simple to operate control panel
Afterburner Preheat
Incineration Temperatures in Excess of 900 degrees C
3 mm Steel Casing and Fully insulated
Dense Refractory Concrete Lining Rated to 1400 degrees C
Solid Hearth to Allow Maximum Burnout
Large Top Opening Lid For Easy Loading
Stainless Steel Flue as standard
12 Months or 1000 hours
Optional Stainless Steel Casing
Heat Recovery System option
3.13
Fuel and Capacity
1.
Low sulphur fuel
2.
Capacity (Cubic Mtr)
.10
3.
Average Capacity
40kg
4.
Fuel Consumption (ltrs / hr)
3
External Dimensions
1.
Length (mm) 735
2.
Width (mm) 500
3.
Height Incl. Flue (mm)
1960
4.
Door Opening (mm)
325 x 325
Internal Dimensions
1.
Length (mm)
620
2.
Width (mm)
390
3.
Height
500
Operation
Minimum Operating Temperature 950
Maximum Operating Temperature 1320
3.
Burn rate per hour
5-20kgs
4.
Temperature Monitoring
Available
Particulate Removers
A mechanical particulate collector must be incorporated after secondary combustion chamber for removal of particulate pollutants entrained in the flue gas stream. The particulate collectors may include any of the following or a combination thereof:
Cyclone separator
Electrostatic precipitators
Fabric filters
Chimney /Stack
The chimney should have a minimum height of 10 meters above ground level and clear the highest point of the building by not less than 3 meters for all The topography and height of adjacent buildings within 50 meters radius should be taken into account.
If possible the chimney should be visible to the operator from the feeding
The addition of dilution air after combustion in order to achieve the requirement of these guidelines is
The minimum exit velocity should be 10 m/s and at least twice the surrounding wind speed (Efflux velocity = wind speed x 2) whichever is higher to ensure no down washing of exiting
Point for the measurement of emissions shall be
Control Panel
Control of 2 burners
Timer control 0- 12 hours
Integral fan timer control
Temperature and thermostatic control
SCHEDULE 2
NO:
REQUIREMENTS
SUPPLIER’S REMARKS
1.
Experience
Previous experience in the supply, installation and commissioning of incinerators
2.
1 Year Maintenance Contract
3.
Work rate
at least10kg per day
4.
Design
Basic Plan design to Provide Overall plant layout. With Feed chamber/ charging, Primary Combustion Chamber. Secondary Combustion Chamber. Particulate Scrubbers, Acid Gas Scrubbers, The stack/ chimney.
Fuel oil tank storage should be Mild steel 1000 liters capacity
Chimney Height should be of 10 meters above ground level.
Housing facility with one waste storage room
Provide Housing designs with adequate cross ventilation
Chamber (Afterburner Maximum exit temperature should not be less than 1100oC
5.
Standard control panel
Safety interlock, Fan Starter, Burner on/ off switch/door safety switch, Auto close down switch, temperatures control mechanism.
6.
Combustion Chambers
Primary Combustion Chamber Minimum exit temperature should not be less than 850oC
Secondary Combustion Maximum exit temperature should be not less than 1100oC
SECTION VII
PRICE SCHEDULE FOR GOODS
Price schedule for Supply, Installation, Testing and Commissioning of an incinerator for Turkwel Power Station
1
2
3
4
5
6
Item
Description
Unit of sale
Quantity
Unit price
Total price
1.
Supply, install, and commission the incinerator as specified.
LOT
1
2.
Construct a standard incinerator housing facility as per the drawing and architectural notes provided
LOT
1
4.
Construct one waste storage room (provide specs on room size, construction material etc)
LOT
1
5.
Supply / adhere to the requirement of OSHA 2007 act
49,50,51,60,61,77,78,79,80,81,100
LOT
1
6.
Onsite training of Operation and Maintenance staff.
LOT
1
7.
All the key Spares (Attach a separate List)
LOT
1
8.
Supply and install 1000 liters Fuel oil storage tank and its secondary containment with Diesel oil level indicator and necessary piping with valves for visual checking of fuel level.
LOT
1
9.
Supply of Operation and Maintenance Manuals.
LOT
1
10.
All other items not specified but necessary to complete the Installation. A separate list of these items to be attached.
LOT
1
11.