mobile incinerator design
The Authority may require that the certificate holder have tests carried out by an accredited institution to
determine stack and/or ground level concentrations of the following substances.
Cadmium and compounds as Cd
Mercury Hg
Thallium Tl
Chromium Cr
Beryllium Be
Arsenic As
Antimony Sb
Barium Ba
Lead Pb
Silver Ag
Cobalt Co
Copper Cu
Manganese Mn
Tin Sn
Vanadium V
Nickel Ni
Hydrochloric HCL
Hydrofluoric acid HF
Sulphur dioxide S02
- A 99.99% destruction and removal efficiency (DRE) for each principal organic hazardous constituent (POHC) in
the waste feed where:
DRE = [(Win – Wout)/Win]*100
Where: Win = mass feed rate of the POHC in the waste stream fed to incinerator, and
Wout = mass emission rate of POHC in the stack prior to the release to the atmosphere.
SOLID WASTE INCINERATOR
1
ea
1.5 MMBtu / hr waste combustion, providing 200-250 lb/hr (90-114 kg/hr)
Processing capacity for mixed waste streams with an average gross
HHV of 5500-8500 Btu/lb
Batch Operation: Approx. 1.9 yb3 (1.45 m3) per 4-6 hour operation cycle
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: sales@hiclover.com Email: hicloversales@gmail.com